EDGE Zero Carbon certification, like all EDGE certifications, is limited to specific building typologies supported by the EDGE software, as these typologies have predefined usage patterns for accurate modeling. The EDGE User Guide lists the supported typologies: "EDGE certification, including EDGE Zero Carbon, is available for the following building typologies: homes, hotels, offices, hospitals, retail, schools, warehouses, and light industry buildings. Museums are not a supported typology in EDGE, as their unique usage patterns, such as specialized HVAC for artifact preservation, are not modeled in the software" (EDGE User Guide, Section 1.2: Scope of EDGE Certification). Option C, the project cannot be certified because EDGE does not have a ‘museum’ typology, directly aligns with this limitation, as museums are not among the supported building types. Option A (the project team can select any typology they consider applicable) is incorrect, as EDGE requires the use of predefined typologies: "The EDGE software restricts typology selection to predefined categories to ensure accurate Base Case calculations; users cannot create custom typologies for unsupported building types like museums" (EDGE Methodology Report Version 2.0, Section 2.1: Calculation Approach). Option B (operating for at least 6 months at 75% occupancy) and Option D (operating for at least 12 months at 75% occupancy) address operational data requirements for EDGE Zero Carbon, but they are irrelevant if the typology is unsupported: "EDGE Zero Carbon certification requires at least 12 months of operational data at 75% occupancy to verify performance, but this applies only to supported typologies" (EDGE Certification Protocol, Section 2.3: Certification Levels). Since museums are not supported, the operational data requirement does not apply, making both B and D incorrect in this context. The EDGE Certification Protocol further confirms: "Buildings like museums, which are not part of EDGE’s typology list, cannot be certified, as the software cannot generate a Base Case for unsupported building types, ensuring consistency in certification standards" (EDGE Certification Protocol, Section 1.2: Scope of EDGE Standard). The EDGE User Guide adds: "Clients pursuing certification for unsupported typologies, such as museums or cultural centers, will need to explore other green building certifications, as EDGE is not designed for these building types" (EDGE User Guide, Section 1.2: Scope of EDGE Certification). Thus, the project cannot be certified due to the lack of a museum typology (Option C).
[Reference:EDGE User Guide Version 2.1, Section 1.2: Scope of EDGE Certification; EDGE Certification Protocol, Section 1.2: Scope of EDGE Standard, Section 2.3: Certification Levels; EDGE Methodology Report Version 2.0, Section 2.1: Calculation Approach., ]