Click the Exhibit button.

Click the Exhibit button.

PE-1 and PE-2 are configured with LDP-signaled pseudowires to provide connectivity between CE-1 and CE-2. You notice no connectivity exists between CE-1 and CE-2.

Referring to the exhibit, which two statements describe potential causes for this fault? (Choose two.)

A.

The VC IDs are mismatched.

B.

There is no LSP configured from PE-1 to PE-2.

C.

Interface ge-0/0/0 on PE-1 is down.

D.

There is no LSP configured from PE-2 to PE-1.